Photovoltaic system, nominal power 19.84 kWp in II Conto Energia
Irradiation data: PVGIS CALC
Albedo factor: 0.2
Azimuth [degrees]: -0 ° - E
Tilt [degrees]: 30 °
Efficiency η, 1 (B.O.S.): 79.30%
Annual yield [kWh / kWp]-equivalent hours: 1,260
PV plant power [kWp]: 19.84
Producibility Theoretical plant [kWh / year]: 24,998.4
B.O.S. = Πi (100 - i-th loss) = 79.30% Total losses of the PV system: (100- B.O.S.)% = 20.7% - ref. 56
- It is specified that the plant is in an excellent state of maintenance and conservation, and is efficient above expectations, being characterized by a real average annual producibility of 1,439.87 equivalent hours per year, for an average annual energy produced from the date of entry into operation of 28,567.56 kWh / year, with the economic value of the incentive equal to 11,769.61 € / year -
- System installed on the roof of the buildingm, to be dismantled -